sntp

The machine clock can be synchronized with an NTP server clock using Simple Network Time Protocol (SNTP). Use the "sntp" command to change the SNTP settings.

You can only select either the IP address or host name for the ntp server.

View settings

msh> sntp

NTP IPv4 server address configuration

You can specify the IPv4/IPv6 address of the NTP server.

msh> sntp server "IPv4/IPv6_address"

NTP hostname configuration

You can specify the hostname of the NTP server.

msh> sntp server "hostname"

Deleting NTP server configuration

msh> sntp server clear

Interval configuration

msh> sntp interval "polling_time"

  • You can specify the interval at which the machine synchronizes with the operator-specified NTP server. The default is 60 minutes.

  • The interval can be entered from 0 to 10,080 minutes.

  • If you set to "0", the machine synchronizes with the NTP server only when you turn the machine on. After that, the machine does not synchronize with the NTP server.

  • You can use the SNTP polling function for switches that request packet transmissions from devices to open ports. For example, you may use the SNTP polling function to prevent the IEEE 802.1x authentication from being canceled.

Time-zone configuration

msh> sntp timezone "±hour_time"

  • You can specify the time difference between the machine clock and NTP server clock. The values are between -12:00 and +13:00.