User GuideIM 350/430 series

Settings You Can Configure Using a Web Browser

Use a web browser from networked computers to configure the security settings shown in the following table. (We use Web Image Monitor installed on this machine.)

Device ManagementConfiguration

Category

Item

Setting

Device SettingsLogs

Collect Job Logs

Active

See Specifying Log Collect Settings.

Device SettingsLogs

Collect Access Logs

Active

See Specifying Log Collect Settings.

SecurityUser Lockout Policy

Lockout

Active

For details, see User Lockout Function.

SecurityUser Lockout Policy

Number of Attempts before Lockout

5 times or less.

For details, see User Lockout Function.

SecurityUser Lockout Policy

Lockout Release Timer

Set to [Active] or [Inactive].

When setting to [Active], set the Lockout release timer to 60 minutes or more.

For details, see User Lockout Function.

SecurityUser Lockout Policy

Lock Out User for

When setting "Lockout Release Timer" to [Active], set the Lockout release timer to 60 minutes or more.

For details, see User Lockout Function.

NetworkSNMPv3

SNMPv3 Function

Inactive

To use SNMPv3 functions, set "SNMPv3 Function" to [Active], and set "Permit SNMPv3 Communication" to [Encryption Only]. Because SNMPv3 enforces authentication for each packet, Login log will be disabled as long as SNMPv3 is active.

SecurityNetwork SecurityIPv4/IPv6

FTP

Inactive

Before specifying this setting, set "Network Security Level" to [Level 2] on the control panel.

Security

S/MIME

"Encryption Algorithm": AES-128 bit, AES-256 bit, or 3DES-168 bit

You must register the user certificate in order to use S/MIME.

The administrator must indicate the strength level that can be specified for the encryption algorithm.

For details about specifying an encryption algorithm and registering a user certificate, see Configuring S/MIME.

Device Management

Category

Item

Setting

Address BookDetail InputAdd User/ChangeEmail

User Certificate

You must register the user certificate in order to use S/MIME.