Maintenance

This section describes the parameters that can be set on the Maintenance menu.

Adjust Image Density

Adjusting the print image density can prevent faint spots or smears appearing on printed pages. You can specify a density value between -6 and 3.

Only change this setting from its default value if necessary.

Adjust Print Position

You can adjust the starting position of the printing page.

Only the installed trays appear on the display panel.

  • Bypass Tray

  • Paper Trays 1–3

  • Back Side

Print Test Sheet

You can print the registration test sheet.

  • Paper Trays 1–3

  • Back Side

Replacement Alert

You can specify when the Alert Indicator lights up to prompt users to replace supplies.

Toner, Drum Unit, Toner Cart. (Waste Toner), Maintenance Kit

Default: [Normal]

  • Notify Sooner

  • Normal

  • Notify Later

Curl Prevention

You can control the fuser temperature to prevent paper from curling.

Default: [Off]

  • On

  • Off

Drum Rotation

When streaks appear on the printed image, performing this function may improve the output. Select [Level 1] (normal) or [Level 2] (powerful) drum rotation.

If the problem persists, contact your local service representative.